SunTech Solar Solutions

Kissimmee, Florida

Private website concept: SunTech Solar Solutions is shown as a proposed service, not an operating company.

Solar installer in Kissimmee, FL

SunTech Solar Solutions is a solar quote and installation service for Kissimmee, FL homes whose bill peaks with the air conditioner. It would size solar from that summer peak, not a yearly average, and hand you a monthly load chart, priced sizes and what your utility does with spring surplus.

  • For Kissimmee homes whose bill peaks with A/C
  • Sizes priced from your August peak
  • See what spring surplus earns before signing

Get your free quote Chart your 12 months

Two-storey house with solar panels on its roof, tall palm trees and a waterside garden in late-afternoon sun.
  • 4.8 from 9 reviews
  • Kissimmee, FL
  • (321) 407-7647

Kissimmee, Florida

Solar sized to your August bill, not your yearly average

SunTech Solar Solutions installs around Kissimmee and the 192 corridor, where the air conditioner sets the bill and a yearly average hides it. We size from the summer peak and hand you the monthly load chart behind it.

What customers say

SunTech Solar SolutionsSolar design and installation · Kissimmee, FL

Serving Kissimmee and nearby towns

★★★★★4.8 from 9 Google reviews

What we do

What we do

  1. Summer-peak sizingThe array sized from your highest cooling months, not a flat average.
  2. Monthly load chartTwelve months of use against twelve months of modelled production.
  3. Rooftop solarPanels and layout priced per DC watt against that chart.
  4. Utility interconnectionThe utility application and the permission to operate.

Call or visit

Talk to us

Phone(321) 407-7647Call to book an assessment.
Office100-112 Buenaventura Blvd #443, Kissimmee, FL 34743Parking on site.
EstimatesFree, in writingDesign and price as separate documents.

Get your free quote

Why homeowners pick us

Why homeowners pick us

  • Peak, not averageA Florida bill peaks in August. The system should match that.
  • Chart includedThe reasoning is a document you keep, not a sales line.
  • Free written estimateA design and a price before you commit to anything.

Our story

Our story

  1. Installing across Kissimmee, St. Cloud, Davenport, Poinciana and Celebration.

From your bills to switch-on

Proposed service. Six steps, each ending in something written you can check. Timelines depend on the permit office and the utility.

  1. Bill intake

    You bring 12 months of bills in kWh, interval data if your utility offers it, A/C age and label photo.

    You get An intake checklist (the quote checklist on this site).

  2. Cooling-load read

    You bring Nothing new: the bills do the work.

    You get A monthly load chart: base load, cooling load and your peak month named.

  3. Site read

    You bring About one visit: roof access, attic, main panel and meter.

    You get Notes per roof plane, west-facing area marked, city or county and utility confirmed.

  4. Priced sizes

    You bring Your questions on the load chart.

    You get Size A, Size B and a middle size, solar-only, with $/W against the state benchmark.

  5. Bill model and recommendation

    You bring Your choice of size.

    You get A 12-month bill table per size and one written recommendation with reasons.

  6. Permit, utility and switch-on

    You bring Signatures on the permit and utility pages.

    You get The installer of record named with a DBPR licence number, then permission to operate.

Why a Kissimmee quote should start from August

Size one household's solar two ways. On its yearly average it needs about 8.5 kW of panels; to cover its August bill, about 12.4 kW (illustrative calculation, worked through below). A kilowatt (kW) measures system size; a kilowatt-hour (kWh) is the energy your bill counts.

That 3.9 kW gap is the decision. It pushes the system past the 10 kW line where both utilities serving Kissimmee homes start asking for liability insurance. And whether you need those extra panels at all depends on your meter: can spring surplus pay for August, or is it credited at a lower value?

A quote with one number hides this. The U.S. Department of Energy's step-by-step guide for consumers going solar tells buyers to review their bills for how much power they need "annually and seasonally". EcoGen, which publishes a state solar cost index, reports in its Cost Index methodology that an annual-average sizing formula came within 20% of real installed sizes in only 19 of 41 states, so it replaced the formula.

The season also sets the price of each kWh. Kissimmee Utility Authority (KUA), the city's utility, charges 12.310¢ per kWh of base energy for a home's first 1,000 kWh a month and 13.575¢ above that, before fuel, conservation charges and taxes (rate schedule effective January 1, 2026). In the example home, August's 1,550 kWh crosses that line by 550 kWh, so cooling kWh are the dearest ones solar can replace.

Sized to cooling does not mean always bigger. How we work. The quote would show the August gap and three ways to close it:

  1. Banked spring credit. Let the yearly-average size (Size A) carry spring surplus into summer, where your utility's rule allows it.
  2. More panels. Buy the August size (Size B) and accept the Tier 2 costs above 10 kW.
  3. A lower peak first. Cut August use with an energy survey or air-conditioner work, then size to the smaller peak.

Then it would recommend one size, with reasons. Service for any address covers these towns.

What would be included, and what would be optional

We include the bill intake, the cooling-load read, the site read, the priced sizes, a month-by-month bill model for each size, and a written recommendation. Three pieces would be optional, each priced on its own line: the peak-reduction sheet, pricing for a west-facing layout, and monitoring that shows monthly output against use. Financing, battery design and backup power are not part of this proposal.

The assessment: your address first, then your cooling load

How we work. The assessment would settle the address first, because it decides who issues your permit and what your surplus earns:

  1. City limits. A Kissimmee mailing address is not proof you live in the city. The city's File for a Permit page makes this step one and links a city-limits lookup. Inside, the City of Kissimmee permits the work; outside, Osceola County does.
  2. The name on your bill. City of Kissimmee homes are on KUA. Unincorporated "Kissimmee" addresses, including Buenaventura Lakes, may be on KUA or on Duke Energy Florida. KUA's territory page is only a map image, so check the bill.
  3. Your cooling load. Base load is what the house uses in the mildest months, usually December to February. Cooling load is the extra kWh in the air-conditioning months, June to September. Highest month minus lowest month gives a first estimate.
  4. The site read. Roof planes and direction, shade along the summer sun path, attic heat, the main panel and the meter. West-facing area is noted because it produces later in the afternoon. The site read would take about one visit. The Department of Energy also suggests checking the roof's age in local permit records.
  5. Association rules. Florida Statute 163.04 bars covenants that prohibit solar, but a homeowners' association may set the roof location within 45° east or west of due south, if that does not impair effective operation. A due-west plane falls outside that cone, so ask the association before design starts.
  6. Peak-first option. On KUA, ask for its free in-home energy survey: a KUA Certified Energy Auditor checks windows, insulation, duct work, water heating, and cooling and heating systems. On a Duke address, start with an A/C contractor's tune-up or replacement quote. The U.S. Treasury's guide to buying and financing solar also advises efficiency improvements before you agree to a salesperson's program.

Bring these

  • 12 months of bills showing kWh by month, not only dollars.
  • Hourly (interval) usage data, if your utility account offers a download.
  • The air conditioner's age, tonnage and a photo of its SEER or SEER2 efficiency label.
  • Your thermostat schedule, and pool pump run hours.
  • Any roof or electrical work already planned.

What you'd get in writing

"12 kW, here's the price" gives you nothing to check. How we work. The written quote would hold five documents:

Deliverable What it answers Decision it settles
Monthly load chart Base vs cooling kWh each month, peak month named Whether your bill is really an August problem
Sizing sheet Size A, Size B and a middle size at or under 10 kW: kW DC, panel count, solar-only price, $/W vs the state benchmark, tier flag What the cooling peak costs in panels
12-month bill table, per size Production vs use by month, surplus and shortfall valued at your meter's actual rule, plus the minimum bill Whether banked credit or more panels covers August
Peak-reduction sheet (optional) What a KUA survey, A/C tune-up or replacement, attic insulation or pool-pump timer changes in Size B, each priced Whether to cut the peak before buying panels for it
Recommendation One size with reasons; installer of record, permit office, utility step Who does the work, under which rules

The recommendation would name the installer of record with a Florida license number you can check on DBPR's Verify a Licensee search: a solar contractor, or another certified or registered contractor working within its scope.

kW DC is the panels' combined direct-current rating. Panels make direct current (DC); the inverter turns it into the alternating current (AC) your house uses. Quoting in DC keeps every price comparable.

Illustrative calculation: one Kissimmee bill, three sizes

Illustrative calculation. Example inputs, not a real home or a quote. Yearly use: 13,248 kWh (12 × 1,104 kWh, EcoGen's Florida average month; state input). August 1,550 kWh, January 820 kWh (example inputs), so cooling adds about 730 kWh in August. Yearly output: 1,555 kWh per kW, EcoGen's Florida factor, referenced to Jacksonville (state input, not a Kissimmee measurement). August output: 125 kWh per kW (example input; a real quote uses an NREL PVWatts result for your roof). Prices: EcoGen's Florida State benchmark, $2.46 per watt.

Illustrative calculation Size A: yearly average Middle: Tier 1 line Size B: August peak
Method 13,248 ÷ 1,555 10 kW cap 1,550 ÷ 125
Size 8.52 kW DC 10.0 kW DC 12.4 kW DC
Price at $2.46/W (State benchmark) about $20,958 $24,600 about $30,504
August output (example factor) about 1,065 kWh 1,250 kWh 1,550 kWh
August shortfall about 485 kWh about 300 kWh none
Yearly output about 13,248 kWh about 15,550 kWh about 19,282 kWh
Utility tier Tier 1 Tier 1, at the limit Tier 2

Whether KUA measures the 10 kW line in AC or DC is not stated, so ask. EcoGen's Florida cost page describes the line as 10 kW AC, about 11,764 W DC; Size B crosses it either way.

Size B covers August outright. It also makes about 6,034 kWh a year more than the home uses, for about $9,546 more than Size A (illustrative calculation). What that surplus is worth depends on the meter:

  • On Duke Energy Florida, year-end leftover credit is paid at a rate based on Duke's COG-1 as-available tariff. EcoGen puts that at typically 3 to 4¢ per kWh, so 6,034 kWh brings roughly $181 to $241 a year (illustrative calculation).
  • On KUA, the tariff does not state the per-kWh value. Until KUA puts it in writing, no installer can honestly price Size B's extra output.

Now the August bill itself. At 1,550 kWh, August base energy on KUA is about $197.76 (1,000 × 12.310¢ + 550 × 13.575¢), before the customer charge, fuel, conservation charges and taxes (illustrative calculation). Each kWh above 1,000 costs 1.265¢ more than the first 1,000.

Peak-first changes the arithmetic. If A/C or insulation work cut August by 300 kWh (example input, not a promised result), Size B drops to 1,250 ÷ 125 = 10.0 kW, on the Tier 1 line instead of past it.

The answer changes next door: in St. Cloud, OUC now credits exported power in dollars, not banked kWh.

What drives the price, and a solar-only $/W check

A quote's total mostly follows from these lines:

  • System size in kW DC. At any given price per watt, cost rises with every kW, and the cooling peak is what sets the kW.
  • Panels and inverter. Model, wattage, inverter type.
  • Roof work. On its own line.
  • Electrical upgrades. A main-panel upgrade, if needed.
  • Tier 2 costs. Above 10 kW, KUA charges a $320 non-refundable fee and requires $1,000,000 of liability insurance; ask your insurer what that coverage adds to your premium.
  • Permit fees. Set by the city or county.

To check the solar part, remove any battery or roof lines and divide the solar-only price by the DC watts. Compare with EcoGen's Florida solar cost benchmark of $2.46 per watt (State benchmark): a modeled installed cash price before incentives, solar only, EcoGen Solar Cost Index September 2026 Edition, prices as of September 25, 2026. EcoGen says most Florida quotes fall between $2.10 and $2.70 per watt (February 2026 data) and calls the index a benchmark, not a quote for your home.

Illustrative calculation. $26,000 solar-only for 10,400 W DC = $2.50 per watt: 4¢ above the $2.46 State benchmark, inside the $2.10 to $2.70 range. It is a reason to ask what the extra 4¢ covers, nothing more.

Two tax rules and one expired credit:

Permits: City of Kissimmee or Osceola County

The city-limits check decides the office.

City of Kissimmee Unincorporated Osceola County
Office Permitting Division Community Development Department
Where you apply or track EnerGov Citizen Self-Service portal Online Permit Center; search permits at permits.osceola.org
What applies to solar "Solar Panel" is its own permit type; Electrical and Re-Roof are separate types Solar panel installation is on the county's residential permit list
Ask your installer Which permits they will pull The permit number, to track it

See the city's types of permits and the county's permit information page, where fees are due when the permit is pulled.

Florida's HB 803 permitting changes have applied in Kissimmee since July 1, 2026. The city says electrical work, roofing, projects of $7,500 or more and flood-zone work always need a permit. Rooftop solar involves electrical work and has its own permit type, so a contractor's "no permit needed" is not enough.

Davenport splits between the city, Polk County and Osceola County, so the same check comes first there.

KUA or Duke: who connects you and what surplus earns

The permit lets you build. The utility lets you switch on, and its rule values the spring surplus in your bill table.

KUA Duke Energy Florida
Who it serves here City of Kissimmee and some unincorporated addresses Some unincorporated addresses (check your bill)
Surplus credit Bill credit set under a three-way agreement of the Florida Municipal Power Agency (FMPA), KUA and you; rate not stated in the tariff kWh credited to next month's use
Carryover Credits carry forward Up to 12 months
Leftover credit Paid when you close the account Paid at year end at a rate based on the COG-1 as-available tariff
Tier 2 (above 10 kW, up to 100 kW) $320 non-refundable fee plus $1,000,000 liability insurance Insurance of up to $1 million; ask the fee
Ask in writing ¢ per exported kWh; AC or DC tier line Current tariff sheet and Tier 2 fee

KUA. KUA's net metering page sets the order: the permit or a Notice of Commencement comes first, then the interconnection application. A Notice of Commencement (NOC) is the recorded notice that construction is starting. KUA allows up to 5 business days to confirm receipt, up to 30 days to approve, and up to 10 business days to set a bidirectional meter and grant permission to operate (PTO). You still pay at least KUA's minimum charge. Do not let anyone call KUA's export credit "full retail".

Duke Energy Florida. As an investor-owned utility, Duke is bound by Florida PSC Rule 25-6.065. Surplus becomes a kWh credit on next month's bill, rolls for up to 12 months, and the leftover is paid out. So banked spring credit can cover August on Duke, and Size A can be enough. Most of Belle Isle is on Duke, where spring kWh bank into summer; in Orlando, OUC or Duke serves a home depending on its address.

From signed quote to permission to operate

Ask your installer to name the owner of each step.

  1. Size sign-off. You choose A, B or the middle size. Owner: you.
  2. Permit application. Filed with the City of Kissimmee through EnerGov, or with Osceola County. Owner: the installer of record. Ask who records the Notice of Commencement.
  3. Utility application. On KUA, filed once the permit or NOC is in place, with your signature on the customer pages; KUA then reviews it, so permit and utility steps can overlap. On Duke, ask for the steps in writing. Owner: installer, with you.
  4. Installation to the approved plans. Owner: installer.
  5. Inspection, requested through the city or county. Owner: installer; you provide access.
  6. Bidirectional meter and PTO. Owner: the utility.
  7. Switch-on, only after PTO.

KUA's limits are maximums, not a promised timeline; the Department of Energy notes permits and inspections can take weeks to months.

After switch-on: hold the system to the sizing sheet

A monitoring app shows production. It cannot tell you whether the system does what the quote said, so keep the sizing sheet and bill table, and compare each month's output against the prediction.

  • Watch the trend. The Department of Energy says a year-over-year production drop of more than 10% may point to a maintenance issue.
  • Plan for the inverter. DOE says panels usually last 20 to 25 years and string inverters 10 to 15; microinverters are closer to panels. Ask which you are buying.
  • Match warranty to loan. The Treasury guide suggests checking that the panel warranty outlasts any loan and that homeowner's insurance covers the system.
  • Selling the house. On KUA, the new owner files a "New Owner RGS Packet" with a notarized first page. Pass on the sizing sheet and monitoring login too.

Choosing a solar installer in Kissimmee: questions to ask before you sign

Use these with any Kissimmee quote, including one from the service, alongside the quote checklist on this site.

  1. Which month is my peak, and how much is cooling? Ask for a monthly load chart.
  2. What do Size A, Size B and a 10 kW middle size cost? Each with kW DC, panel count and tier.
  3. What is the solar-only price per DC watt? Compare it with the $2.46 State benchmark.
  4. Which utility's surplus rule did you use? KUA or Duke Energy Florida, written out.
  5. On KUA, what is an exported kWh worth, and is the 10 kW line AC or DC? If unsure, ask KUA in writing.
  6. Which office issues my permit? City or county, from the city-limits lookup.
  7. Who is the installer of record, and what is their DBPR license number? Look it up, and ask whether a subcontractor installs.
  8. Who files the Notice of Commencement and the utility application?
  9. What would a lower August peak change? Get each option priced separately.
  10. Does the contract allow a lien, and can I use my own financing? The Treasury guide flags UCC-1 liens and says you need not take the salesperson's financing.
  11. Is anything "free"? Treasury treats "free" claims and pressure to sign as red flags. Get promises in writing.
  12. Do I get a monitoring login on day one?

Short answers

Is there still a 30% federal solar credit?

Not for a home system installed now; it ended for property placed in service after December 31, 2025. Some Kissimmee solar pages we read still promise it until 2032.

Will KUA pay full retail for my surplus?

KUA's tariff credits surplus under its FMPA agreement without stating a rate. Ask KUA for the value per exported kWh in writing before sizing for surplus.

Do I get a check for leftover credit at year end?

On Duke Energy Florida, leftover credit is paid after the 12-month carryover at a COG-1-based rate. On KUA, unused credit is paid when you close the account. Either way, a large leftover means panels whose output earns a lower or unknown value, which is why the August numbers come first.

Chart your cooling peak

Type the kWh from each month of your last twelve bills. The sizer draws your year, finds the peak month and compares two sizes: one built from the yearly average (Size A) and one built from the peak month (Size B). It runs on this device; nothing is sent or stored.

It starts with an illustrative household (13,248 kWh a year), not a real home. Sizes are rough first estimates for comparing quotes, not a design.

kWh per month
Peak month
August, 1,550 kWh
Cooling in the peak month
730 kWh above January
Size A, yearly average
8.52 kW DC
Size B, peak month
12.40 kW DC
The gap
3.88 kW more for Size B; Size B is above the 10 kW line where Tier 2 insurance rules start (ask your utility whether the line is AC or DC)
At $2.46 per watt (State benchmark)
Size A about $20,958; Size B about $30,504

State benchmark: EcoGen Solar Cost Index, Florida, September 2026 Edition, a modeled solar-only cash price before incentives. Size B covers the peak month outright; whether you need it depends on what your utility pays for spring surplus.

Output per kW of panels
Florida state input (EcoGen), not a Kissimmee measurement
Example input; a real quote uses a PVWatts result for your roof
Overhead view of a tile-roofed home with solar panels, two swimming pools and a lake beside the garden.

Four nearby town guides

Each guide covers what changes the size of a quote in that town: the permit office, the utility at the address and how it credits spring surplus. Coverage is proposed and not confirmed.

Get your free quote

Pick your town and what you want priced. The site builds a checklist to take to any installer's quote visit, with your peak sizer numbers if you charted them. It runs on this device: nothing is sent or stored.